CHBNS Single-phase Input VFD from a China manufacturer brings adjustable motor control to sites with 1-phase 220 V supply. The documented 0.4–2.2 kW range adds vector/V-F modes, programmable I/O, PID, multi-speed operation, and compact mounting dimensions for small machinery and OEM panels.
CHBNS, a China manufacturer and supplier, develops the Single-phase Input VFD page around the motor, load, command path, protection, and commissioning evidence. This input-drive arrangement addresses a common infrastructure constraint: the machine location has 1-phase 220 V supply, but the process still needs controlled acceleration, deceleration, speed, direction, and monitoring. The E-series installation table documents 0.4, 0.75, 1.5, and 2.2 kW input models, while the parameter manual adds multiple motor-control modes and programmable machine functions. The exact motor output wiring and current must be confirmed from the ordered model before installation.
How it works
Use single-phase supply without treating it as a shortcut
A correct design checks input current, upstream protection, motor output requirements, and the real load instead of selecting only by kilowatts.
01
Verify the incoming circuit
Confirm 1-phase 220 V tolerance, breaker and cable capacity, grounding, isolation, and the available continuous current.
02
Match the motor and load
Enter the correct rated voltage, current, frequency, speed, and power; then choose V/F or vector mode for the application.
03
Commission the machine
Set ramps, direction, minimum and maximum frequency, I/O logic, and protection, then test under a representative load.
Core product advantages
Why this control architecture earns its place
The Single-phase Input VFD concentrates its value in controllability, integration, and documented selection boundaries rather than broad company claims.
01
Works with 1-phase infrastructure
The documented input family lets smaller sites plan variable-frequency control where three-phase incoming service is unavailable.
02
Four documented power points
The manual table lists 0.4, 0.75, 1.5, and 2.2 kW models with output-current and enclosure-size data.
03
Control beyond basic speed
V/F, advanced V/F, simple vector, advanced vector, torque, PID, multistage, and programmable terminal functions are documented.
Product specifications
Quote the manual, then confirm the order code
0.4 kW
2.5 A output; 85 × 143 × 116 mm bodyD1 126 mm; 4.5 mm mounting hole
0.75 kW
5 A output; 85 × 143 × 116 mm bodyD1 126 mm; 4.5 mm mounting hole
1.5 kW
7 A output; 85 × 143 × 116 mm bodyD1 126 mm; 4.5 mm mounting hole
2.2 kW
10 A output; 100 × 151 × 120 mm bodyD1 130 mm; 4.5 mm mounting hole
Up to 999.9 Hz documentedMotor and machine limits still govern
External architecture comparison
Compare the system, not another CHBNS product
This drive is most useful when the external supply constraint is real and the motor-drive system is designed around it. Compared with improvised phase-conversion or fixed-speed architectures, it provides documented model currents, ramps, monitoring, and control functions; upstream current demand and derating still require engineering review. This comparison avoids unsupported claims about named competitors and shows where the Single-phase Input VFD changes the machine-design decision.
Fixed-speed single-phase motorSimple supply connection, but limited programmed speed control and machine I/O.
Improvised converter chainMore devices and interfaces can increase wiring, enclosure, diagnostic, and responsibility boundaries.
Documented E-series VFDA defined 1-phase 220 V model table plus programmable control and monitoring in one drive family.
Product Application
Explore how our products are applied across industries and use cases.
Small workshop machine
Add controlled start, stop, and speed where only a 1-phase 220 V circuit is available.
Compact conveyor
Set line speed and ramps while checking available input current and motor torque at low speed.
Packaging or feeding unit
Use programmable terminals or multistage speed for defined machine states and changeover recipes.
Fan or pump skid
Apply PID only after the sensor signal, process direction, sleep logic, and motor cooling are verified.
Product detail
See the enclosure, interface, and access points
E-series control and power terminalsE-series enclosure and keypad angle
Manuals & Packaging
Original manual and packaging images for reference and verification
E-series manual page: 1-phase 220 V model currents and dimensionsCHBNS branded packing context
CHBNS factory, packing, or shipping photographs show general production and export context only. They are not presented as a certificate, batch inspection report, or delivery record for this exact page.
What the inquiry and release package should contain
China factory model and availability confirmation
Motor nameplate and load review
Wiring, I/O, and protection schedule
Parameter backup and accepted speed limits
Representative loaded test record
Packing, document, and shipment requirements
For OEM, wholesale, distributor, and custom sourcing, the manufacturer can review model coding, documentation, packaging, and sample requirements before mass-order release. Final quality acceptance follows the agreed specification, not a generic web statement.
FAQ
Does single-phase input mean single-phase motor output?
Do not assume that. Verify the output arrangement and compatible motor from the ordered model manual and terminal diagram before wiring.
Why is the upstream current important?
A single-phase source can draw substantial current for the same motor power. The breaker, cable, voltage drop, supply capacity, and duty cycle must be checked.
Can a 2.2 kW drive always run a 2.2 kW load?
Not automatically. Motor current, starting demand, overload profile, ambient temperature, switching frequency, and mechanical load determine the final selection.
Request a factory-direct quotation or price list for CHBNS gear motors, reducers and AC drives. Send your model, quantity and OEM customization needs to discuss a bulk order.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy